Port BUSACCESS - CAPTURE-LIN

Capture access to LIN

此端口要求安装 PCAP 驱动。

Stimulation

此端口不具备激励能力。

Name

在以下情况下可用

默认值

有效值

Type

Description

网络接口卡

[ONLINE]

string

Used network interface card

Logger protocol

PLP/TECMP

[PLP/TECMP, ASAM CMP]

string

Which logger protocol is used.

Do not stop RBS

☐

bool

Restbus simulation stays active beyond test case execution.

Probe ID / Device ID

Logger protocol: ‘PLP/TECMP’

0

int

Identifier of the probe / device

Bus Spec ID / Interface ID

Logger protocol: ‘PLP/TECMP’

0

int

Identifier of the bus specification / interface

Device-ID and Stream-ID

Logger protocol: ‘ASAM CMP’

‘(0,0)’

string

Tuple consisting of device ID and stream ID, e.g.: (0,0)

Interface-ID

Logger protocol: ‘ASAM CMP’

0

int

Identifier of the interface

LIN version

‘1.3’

[‘1.3’, ‘2.0’]

string

LIN protocol version to be used. Only affects calculation and validation of the frame checksum.

1.3 = received frames must have a classic checksum.

2.0 = received frames may have enhanced or classic checksum.

If the database does not define a checksum mode for a specific frame to be sent, this option will be taken into account to use either classic (1.3) or enhanced (2.0) checksum mode.

Bus-DB

string

ClearFrame

清除指定帧的接收缓冲区

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

FrameId

int

Frame ID

返回值

Name

在以下情况下可用

默认值

有效值

Type

Description

result

ByteStream

ByteStream

DeregisterFrameForInbox

Ungeristers a frame that is being streamed to an inbox

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

FrameId

int

Frame ID

Inbox

object

现有收件箱

GetFirstValue

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

FrameName

string

Frame name

NodeName

string

电子控制单元的名称

RawValue

False

[False, True]

bool

如果为 ‘True’,则返回原始值。

Reset

False

[False, True]

bool

若为 ‘True’,则第一个接收到的值在被读取后将被删除

SignalName

string

信号名称

InitFrame

Registers the frame for use with other jobs

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

FrameId

int

Frame ID

ReadFrame

Reads the given frame ID (use InitLinFrame before!)

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

doDelete

False

[False, True]

bool

若为 “True”,则在读取后删除该帧

FrameId

int

Frame ID

返回值

Name

在以下情况下可用

默认值

有效值

Type

Description

result

ByteStream

ByteStream

ReadFrameEx

Reads the given frame ID (use InitLinFrame before!)

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

doDelete

False

[False, True]

bool

若为 “True”,则在读取后删除该帧

FrameId

int

Frame ID

返回值

Name

在以下情况下可用

默认值

有效值

Type

Description

result

object

LinFrame

RegisterFrameForInbox

注册一个帧,以便将其流式传输到 Inbox。

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

FrameId

int

Frame ID

Inbox

object

现有收件箱

saveAsLinFrame

False

[False, True]

bool

If True, the frame is saved as a LinFrame object, else as a ByteStream

ResetFirstValue

清除给定信号的第一个已接收值

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

FrameName

string

Frame name

NodeName

string

电子控制单元的名称

SignalName

string

信号名称

SendFrame

All in one: Set data, temporarily enable a frame, and send a master request. Frame ID must be registered in advance via the job “InitFrame”.

Parameterization

Parameter

Name

在以下情况下可用

默认值

有效值

Type

Description

checkSumMode

‘Default’

[‘Enhanced’, ‘Classic’, ‘Default’]

string

Mode of the checksum calculation. With default the LIN version from the TBC is used for the determination.

DataByteStream

ByteStream

要发送的数据

FrameId

int

Frame ID